Module Installation Procedure in XM2 Power Supplies, continued

6. Plug the supplied 18-pin jumper into the header on the back of the DSM3 Series circuit board.

8. Fasten the DSM3 Series to the Inverter Module by tightening the two captive screws. It

is recommended that the screws be tightened alternately, a few turns at a time so the

Communications Module aligns in parallel to the Inverter Module.

9. Reinstall the Inverter Module and reconnect the ribbon cable. Make front panel connections

(tamper, temperature sensor, battery sense, RF etc.).

10. If not yet done, record the cable modem MAC address from the front of the unit and report it to

the network manager for network provisioning.

7. Line up the 18-pin jumper with the header on the Inverter Module and gently push the DSM3

Series into the Inverter Module.

Fig. 7-3, The 18-pin jumper

(Alpha p/n 540-286-19)

Fig. 7-5, Connecting the Communications Module to the Inverter Module

Fig. 7-4, The 18-pin jumper installed

7.0 Installation

To prevent damage to the DSM3, do not reuse the existing 18-pin connector.