Housing dimensions – Burkert Type 1150 User Manual

Page 16

Advertising
background image

14 - 1150

S

YSTEM

DESCRIPTION

Housing

Dimensions

Housing type

housing and back panel: metal for panel mounting as per DIN 43700

Front bezel

plastic to UL 94 V0 144 mm x 130 mm

Mounting depth

170 mm

Panel cut-out

92+

0,8

x 92+

0,8

mm

Ambient/storage temperature range

-5 to 50 °C / -40 to +70 °C

Climatic conditions

rel. humidity

75 % annual mean, no condensation

Operating position

horizontal

Enclosure protection

to EN 60 529,

front IP 65, rear IP 20

Weight (fully fitted)

approx. 1400 g

Membrane keypad

polyester film, resistant to normal washing and cleaning agents

Rear view

setup plug

18

162

170

188

Panel cut-out
to DIN ISO 43 700

Front view

Side view

92

+0,8

0

92

+0,8

0

91.5

91.5

130

144