1150 - 73

C

ONFIGURATION

Value / selection

Description

Inhibit program start
Program start
Program stop
Program cancel
Program selection
Fast forward

Segment change

Program cannot be started
Program start
Program stop
Program cancel
Programselection (see below)
Dynamic speed increase of program sequence

Segment change

Display text

Standard text
Text 1

...

Text 100

No text

System texts according to function
Definable texts (only via setup program)

No entry in event list

Delay

0 to 9999 s

An info or an alarm is only activated with delay

(see "Message types")

Message

No

Yes

Defines whether an info is produced when the logic function is activated.

Alarm

No

Yes

Defines whether an alarm message is produced when the logic function is

activated.
Alarms must be acknowledged.

Should the info be displayed immediately:
just set info to “yes”

Should the info be displayed after a delay:
set info to “yes” and enter delay time

Should the alarm be displayed immediately:
just set alarm to “yes”

Should the alarm be displayed after a delay:
set alarm to “yes” and enter delay time

Should the info change to alarm after a delay time:
set info and alarm to “yes” and enter delay time.

Message types

Logic input 1 (2 to 6) / ...
Limit comparator 1 (2 to 16) / ...
Logic 1 (2 to 8) / ...
Control contact 1 (2 to 8) / ...
Tolerance band signal / ...
Program end signal / ...
Ramp end signal 1 (2 to 4) / ...