60 - 1150

C

ONFIGURATION

Generator

The basic function of the instrument is defined here. The instrument with all the
available controller channels can be operated as a fixed setpoint controller, program
controller or program generator.

Furthermore, ramp functions (fixed-setpoint controller) can be activated for the indivi-
dual controller channels with different parameters defined for the program controller/
generator.

Configuration

Analog inputs

Controller

Generator

Limit comparators

Outputs

Logic functions

Math / logic

C-level

Display

Interfaces

Device data

Recording

Function / ...

Value / selection

Description

Function

Fixed-setpt.contr.
Progr.contr.
Progr.gen.

Basic instrument function

Ramp function

A rising or a falling ramp function can be implemented. The ramp-end value is determined by the setpoint
input.

The ramp function can be stopped and canceled via the logic functions (see Chapter “Logic functions”).

The ramp function is interrupted on a probe break, or for manual mode. The outputs react the
same as for overrange/underrange (user configurable).