Burkert Type 1150 User Manual

Page 74

Advertising
background image

72 - 1150

C

ONFIGURATION

Selection of functions

Logic input 1 (2 to 6) / ...
Limit comparator (2 to 16) / ...
Logic 1 (2 to 8) / ...
Control contact 1 (2 to 8) / ...
Tolerance band signal / ...
Program end signal / ...
Ramp end signal 1 (2 to 4) / ...

Value / selection

Description

Start Tune C1
Cancel Tune C1
Manual/Auto C1

Inhibit Manual C1

Start Tune C2
Cancel Tune C2
Manual/Auto C2

Inhibit Manual C2

Start Tune C3
Cancel Tune C3
Manual/Auto C3

Inhibit Manual C3

Start Tune C4
Cancel Tune C4
Manual/Auto C4

Inhibit Manual C4
Ramp stop C1

Cancel ramp C1
Setpoint switching C1

Proc. val. switching C1
Paramset switching C1
Ramp stop C2

Cancel ramp C2
Setpoint switching C2

Proc. val. switching C2
Paramset switching C2
Ramp stop C3

Cancel ramp C3
Setpoint switching C3

Proc. val. switching C3
Paramset switching C3
Ramp stop C4

Cancel ramp C4
Setpoint switching C4

Proc. val. switching C4
Paramset switching C4
Key inhibit
Level inhibit

Text display

Display off
Display changeover

Acknowledgement LK

Prg.Auto/Man. switching
Inhibit prgramm start
Program start
Program stop
Program cancel
Program selection
Fast forward
Segment change

Start self-optimization for controller 1
Cancel self-optimization for controller 1
Changeover to manual mode for controller 1

Inhibit manual mode for controller 1

Start self-optimization for controller 2
Cancel self-optimization for controller 2
Changeover to manual mode for controller 2

Inhibit manual mode for controller 2

Start self-optimization for controller 3
Cancel self-optimization for controller 3
Changeover to manual mode for controller 3

Inhibit manual mode for controller 3

Start self-optimization for controller 4
Cancel self-optimization for controller 4
Changeover to manual mode for controller 4

Inhibit manual mode for controller 4
Ramp stop for controller 1
Ramp OFF for controller 1

Setpoint switching for controller 1
Process value switching for controller 1
Parameter set switching for controller 1 (0 = parameter set 1)
Ramp stop for controller 2
Ramp OFF for controller 2
Setpoint switching for controller 2
Process value switching for controller 2
Parameter set switching for controller 2 (0 = parameter set 1)
Ramp stop for controller 3
Ramp OFF for controller 3
Setpoint switching for controller 3
Process value switching for controller 3
Parameter set switching for controller 3 (0 = parameter set 1)
Ramp stop for controller 4
Ramp OFF for controller 4
Setpoint switching for controller 4
Process value switching for controller 4
Parameter set switching for controller 4 (0 = parameter set 1)
Key inhibit
Level inhibit
Text display
Screen OFF
Switch over screen templates
Acknowledgement of limit comparators
Changeover between automatic and manual
Program cannot be started
Program start
Program stop
Program cancel
Program selection (see below)
Dynamic speed increase of programm sequence
Segment change