Technical data, Conditions of use, Conformity to standards and directives – Burkert Type 8076 User Manual

Page 16: Conformities common to the 8026 and the se36

Advertising
background image

14

Technicaldata

6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature

-10 to +60 °C

Air humidity

< 85%, non condensated

Protection rating

IP67 and IP65 with connectors plugged in and tightened and electronic
module cover fully screwed down

6.2.

conformity to standards and directives

6.2.1.

conformities common to the 8026 and the se36

• EMC: EN 61000-6-2, EN 61000-6-3

• Vibration: EN 60068-2-6

• Shock: EN 60068-2-27

For UL devices (

) in the United States of America and Canada:

• UL 61010-1

• CAN/CSA-C22.2 n° 61010-1

6.2.2.

conformity to the pressure directive of flowmeters 8026
and fittings s030 and s070

The devices 8026 and the fittings S030 and S070 comply with article 3§3 of the pressure directive.

Acc. to the 97/23/CE pressure directive, the product can only be used in the following cases (depending on max.
pressure, pipe diameter and fluid):

type of fluid

conditions

Fluid group 1, par. 1.3.a

• Flowmeter 8026 and fitting S030: DN ≤ 25 only

• Fitting S070: Forbidden

Fluid group 2 par. 1.3.a

DN ≤ 32
or DN > 32 and PNxDN ≤ 1000

Fluid group 1 par. 1.3.b

• Flowmeter 8026: DN ≤ 25 or DN > 25 and PNxDN ≤ 2000

• Fittings S030 and S070: PNxDN ≤ 2000

Fluid group 2 par. 1.3.b

• Flowmeter 8026: DN ≤ 400

• Fittings S030 and S070: DN ≤ 200

English

Type 8026- 8036- 8076

Advertising
This manual is related to the following products: