Technicaldata

fluid pressure

• 8026

• 8036

• 8076 with a fitting S070 of DN15

• 8076 with a fitting S070 of DN25

• 8076 with a fitting S070 of DN40 or DN50

• 8076 with a fitting S070 of DN80

• 8076 with a fitting S070 of DN100

Also refer to the requirements of the Pressure Directive: see
chap. 6.2.2

• PN10; Also factor in the fluid temperature/pressure

dependency for the 8026 inserted into an S020 fitting (see
Figure 5)

• PN16; Also factor in the fluid temperature/pressure

dependency for the 8036 (SE36 mounted on an S030 fitting):
see Figure 6

• max. 55 bar

• max. 55 bar (or the rules governing the flanges)

• max. 18 bar

• max. 12 bar

• max. 10 bar

type of fluid

• 8026 and 8036

• 8076

• Neutral or slightly aggressive fluids

• Viscous fluids, free of solid particles

fluid viscosity

• 8026 and 8036

• 8076

• 300 cSt max.

• Refer to the operating manual for fitting S070

solid particle rate in the fluid

• 8026 and 8036

• 8076

• ≤ 1%

• 0 %

flow rate measurement

• Measurement range

• Linearity

• Repeatability

• Measurement error with standard K factor

• measurement error with a Teach-in

procedure

• 0,3 to 10 m/s

• ±0,5%

2)

of the full scale

• ±0,4%

2)

of the measured value

• ±2,5%

2)

of the measured value

• ±1%

2)

of the measured value (at the teach-in point)

1)

and PVDF paddle wheel

2)

Determined in the following reference conditions: fluid = water, water and ambiant temperatures = 20 °C, upstream and

downstream distances respected, appropriate pipe dimensions.

6.3.3.

electrical data

Power supply

• version with 2 or 3 outputs (2 wires)

• version with 4 outputs (3 wires)

• 14-36 V DC, filtered and regulated

• 12-36 V DC, filtered and regulated