Recommendations on installing an 8076 on a pipe, Figure 13), Figure 14) – Burkert Type 8076 User Manual

Page 28

Advertising
background image

26

Installationandwiring

SE36

S030

1

2

3

SE36

S070

1

2

1: Insert the electronic module in the sensor holder.

2: Turn the electronic module by a quarter turn.

3: Secure the electronic module and the S030 fitting only, by
tightening the screw with a suitable tool to a max. tightening
torque of 1 Nm.

Figure 13 :

Assembling the SE36 and the fitting S030 or S070

A

B

Check that there is a seal on the fitting and that it is not
damaged. Replace the seal if necessary.

Place nut A on the fitting and insert circlip B into the groove.

Carefully insert the device into the fitting. If assembly is
correct, the device can no longer rotate on itself.

Secure the unit with nut A, tightening only by hand.

Figure 14 :

Installation of flowmeter 8026 into the fitting S020

Set the K factor parameter (see chap. 9.13.5) or have it determined through a teach-in procedure.

8.2.2.

recommendations on installing an 8076 on a pipe

Install the fitting S070 on the pipe in such a way that the oval gear axes are in the horizontal plane, as shown
in Figure 15.