Mounted version, 12-36 v dc – Burkert Type 8035 User Manual

Page 44

Advertising
background image

42

Installationandwiring

7.6.9

Wiring the Do1 transistor output of a compact, a panel-
mounted or a wall-mounted version, 12-36 v DC

PE

PE

PE

L+

L-

PE P- P+

NC

Iout

PULSE

DO1

Supply

12..36Vdc

Univ

Batch

(AO1)

300 mA

+

-

12-36 V DC

(*)

+

-

+

- 5-36 VDC

PLC

Power supply of

the device

Power supply of

the device

PLC

PE

PE

PE

L+

L-

PE P- P+

NC

Iout

PULSE

DO1

Supply

12..36Vdc

Univ

Batch

(AO1)

300 mA

(*)

+

-

+

- 5-36 VDC

+

-

12-36 V DC

*) If a direct earth connection is not possible, fit a 100 nF/50 V capacitor between the negative power supply terminal and
the earth

Figure 31:

NPN wiring of the DO1 transistor output

Figure 32:

PNP wiring of the DO1 transistor output

Configure transistor output DO1 acc. to chap. “9.7.19” to “9.7.23”.

7.6.10 Wiring the Do1 transistor output of a compact version,

115/230 v AC

Wire the transistor output DO1 as described in chap. “7.6.9”.

Configure transistor output DO1 acc. to chap. “9.7.19” to “9.7.23”.