Danger, Wire the output do4 as described in “figure 36, Plc terminal a – Burkert Type 8035 User Manual

Page 57: Start the device again, Do a dosing as shown in “figure 37”. english, 55 operatingandfunctions

Advertising
background image

55

Operatingandfunctions

9.6.1

Doing a dosing in dosing mode "loC. mAnu." or
"mem.+mAnu."

Dosing mode "LOC. MANU." allows for entering a dosing quantity and starting the dosing, via the navigation keys.

Dosing mode "MEM.+MANU." allows for:

• either entering a dosing quantity and starting the dosing, via the navigation keys,

• or starting the dosing, via the navigation keys, of a quantity saved in the memory.

danger

Danger due to electrical voltage.

▶ Shut down the electrical power source of all the conductors and isolate it before carrying out work on the

system.

▶ Observe all applicable accident protection and safety regulations for electrical equipment.

Connect the valves to the DO2 and DO3 outputs: see chap. “7.6.12”.

Wire the output DO4 as described in “Figure 36”.

CURRENT

SOURCE

SINK

BINARY

PE

PE

PE

PE

DI1

DI2

DI3

DI4

DO4

ISOG

FLOW

SENSOR

L+

L-

PE P- P+

NC

Iout

PULSE

DO1

Supply

12..36Vdc

Univ

Batch

(AO1)

SUPPLY

NC

COIL

PULSE INPUT

NPN/PN

P

2

1

3

PE

+

-

SENSOR

SUPPL

Y

LOAD

+5V

L+

(L+)-12V

COIL/PNP

39K

470

2.2K

SENSOR TYPE

COIL

NPN/PNP

DO2

DO3

OF

FO

N

+

-

5-36 V DC

125 mA

LED

1)

signalling the dosing state for example if the output DO4 has been

configured to transmit the state of the device.

PLC

Terminal A

2)

1)

The LED can be replaced by another indicating system depending on the configuration of the transistor output DO4. See

chap. “9.7.18”.

2)

On a version energized with a 12-36 V DC voltage, the power supply of the device can be used to energize the transistor

output DO4; If this is the case, connect the terminal "ISOG" to the terminal (L-) of terminal block A and use a 300 mA-fuse
(instead of a 125 mA-fuse) to protect the power supply.

Figure 36:

Electrical connection of the transistor output DO4 in the dosing modes "LOC. MANU", "LOC. MEM",
"MEM+MANU" or "LOC. REP"

Start the device again.

Configure the device with the dosing mode "LOC. MANU." or "MEM.+MANU.": see chap. “9.7.6” or “9.7.8”.

Do a dosing as shown in “Figure 37”.

English

Type 8025 - 8035 BATCH