Operatingandfunctions

9.6.6

Doing a dosing in dosing mode "exT. rep."

The dosing mode "EXT. REP." allows for starting, via the digital inputs, the dosing of the quantity determined by a
Teach-In procedure.

danger

Danger due to electrical voltage.

▶ Shut down the electrical power source of all the conductors and isolate it before carrying out work on the

system.

▶ Observe all applicable accident protection and safety regulations for electrical equipment.

Connect the valves to the DO2 and DO3 outputs: see chap. 7.6.12.

Wire the output DO4 and the digital inputs as described in “Figure 49” and depending on the following
requirements:

• the transistor output DO4 allows for transmitting the dosing state.

• when a dosing has been interrupted, the digital input DI1 allows for the navigation within the pause menu,

between the function "CONTINUE" and the function "RESET".

• the digital input DI4 allows for interrupting or continuing a dosing, when the digital input DI1 is active. It also

allows for confirming an alarm, if the generation of alarms has been activated on the device (see chap. “9.7.16”
and “9.7.17”).

CURRENT

SOURCE

SINK

BINARY

PE

PE

PE

PE

DI1

DI2

DI3

DI4

DO4

ISOG

FLOW

SENSOR

L+

L-

PE P- P+

NC

Iout

PULSE

DO1

Supply

12..36Vdc

Univ

Batch

(AO1)

SUPPLY

NC

COIL

PULSE INPUT

NPN/PN

P

2

1

3

PE

+

-

SENSOR

SUPPL

Y

LOAD

+5V

L+

(L+)-12V

COIL/PNP

39K

470

2.2K

SENSOR TYPE

COIL

NPN/PNP

DO2

DO3

OF

FO

N

+

-

5-36 V DC

125 mA

LED

1)

signalling the dosing state for example if the output DO4 has been

configured to transmit the state of the device.

System enabling to start and interrupt the dosing.

Switch

Terminal A

PLC

2)

1)

The LED can be replaced by another indicating system depending on the configuration of the transistor output DO4. See

chap. “9.7.18”.

2)

On a version energized with a 12-36 V DC voltage, the power supply of the device can be used to energize the digital

inputs DI and the transistor output DO4; If this is the case, connect the terminal "ISOG" to the terminal (L-) of terminal block
A and use a 300 mA-fuse (instead of a 125 mA-fuse) to protect the power supply.