13.1.9 Mass flow + Density


After selecting the Mass flow + Density function, the following will be displayed:

XXX.X kg/h

XXX.X g/cm³



The first line of the LCD shows the current mass flow and the second the density of the measured fluid.
You define the display unit in the FLOW functional class using the Mass flow QM unit function and the
density unit using the Density unit function in the DENSITY functional class.

13.1.10 Mass flow + Temperature


After selecting the Mass flow + Temperature function, the following will be displayed:

XXX.X kg/h

XXX °C

The first line of the LCD shows the current mass flow and the second line the temperature of the
measured fluid. You define the display unit in the FLOW functional class using the Mass flow
QM unit
function.

13.1.11 Volume flow + Counter forward


After selecting the Volume flow + Counter forward function, the current mass flow will be displayed in the
first line of the LCD:

XXX.X m³/h

XXXXXXXX.XX m³


The second line shows the value of the counter forward. The operator can define the display unit in the
FLOW functional class using the Volume flow QV unit function and the counter unit using the Unit of
counters

function in the COUNTERS functional class.

13.1.12 Volume flow + Density


After selecting the Volume flow + Density function, the following will be displayed:

XXX.X m³/h

XXX.X g/cm³



The first line of the LCD shows the current volume flow and the second line the density of the measured
fluid. The operator can define the display unit in the FLOW functional class using the Volume flow QM
unit

function and the unit for density measurement in the DENSITY functional class using the Density unit

function.

CMB & CT OPERATING MANUAL
Part No 06EN003384 rev. 1.6

Page 53 of 106