Density functional class, 6 density functional class – Fluid Components International CMB User Manual

Page 66

Advertising
background image

13.6 DENSITY functional class

The functional class DENSITY is comprised of the functions that affect the lower- and the upper-range
value and the processing of the measured density values. The additional service functions regarding
density calibration will not be described in these instructions.

DENSITY

DENSITY

Density

measurement

on/off

Density

measurement

on/off

Density unit

Density unit

DENSITY

functional class

Measurement

[on]

________________

on
off

fixed

Density in

[g / l]

_______________

kg / l

g / l

g / cm³
lbs / ft³

lbs / USG

Density

lower range val

Density

lower range val

Density 0 % =

0600 g/l

Density

upper range val

Density

upper range val

Density 100 % =

1100 g/l

Density

limit MIN

Density

limit MIN

Density

MIN = 0979.0 g/l

Density

limit MAX

Density

limit MAX

Density

MAX = 1200.0 g/l

Density limit

hysteresis

Density limit

hysteresis

Density limit

Hyst.= 000.5 g/l

Density limit

for empty pipe

Density limit

for empty pipe

Pipe emty below

0500 g/l

Display ref./

Process dens.

Display ref./

Process dens.

Ref.-density

Temp. coeff.

Ref.-density

Temp. coeff.

Ref.-density

Ref. temperature

Ref.-density

Ref. temperature

Ref.-density

Ref. pressure

Ref.-density

Ref. pressure

Display of

[Process density]

________________

Reference density

Process density

Temp.coeff.

+00.000 E-5/K

Ref. temperature

015.00 °C

Ref.pressure

001.000 bar

Fixed density

setting

Fixed density

setting

Fixed density

0998.1 g/l


Page 66 of 106

CMB & CT OPERATING MANUAL

Advertising