13.5.6 Volume flow QV unit
This function allows the operator to define the physical unit for all display functions and the upper-range
value for volume flow. After choosing the “Volume flow QV unit” function and pressing
↵, the following
selection field will be displayed:
Volume flow QV unit
in [m³/h]
According to the description in Section 12.4.3.1 Selection window/make a selection, one of the following
units can be selected:
¾
m³/h,
m³/s
¾
l/h, l/min, l/s
¾
USG/h, USG/min, USG/s
¾
UKG/h, UKG/min, UKG/s
¾
USB/d
¾
MG/d
¾
ft³/min
¾
acft/s
Press
↵ to confirm and save the selection.
13.5.7 Volume flow QV range
This function allows the operator to set the upper-range value for volume flow. The upper-range value
takes on the unit defined using the Volume flow QV unit function. After choosing the Volume flow QV
range
function and pressing
↵, the following selection field will be displayed:
QV range=100 %
XXXXX.XX m³/h
The current upper-range value for volume flow will be displayed. According to the description in Section
12.4.3.2 Input window/modify a value, the current value can be changed. Output and display of the meas-
ured value will only be realized for mass flowmeters for which a density calibration has been carried out.
CMB & CT OPERATING MANUAL
Part No 06EN003384 rev. 1.6
Page 65 of 106