13.3.1 Unit of counters
After choosing the Unit of counters function and pressing
↵, the current forward and reverse counter unit
will be displayed:
Accumulation of:
[kg]
According to the description in Section 12.4.3.1 Selection window/make a selection, one of the following
units can be selected.
¾
Mass units: g, kg, and t as well as lbs, shton and lton
¾
Volume units: m³, and l as well as USG, UKG, USB, ft³ and acf
When the unit is changed, the counters will be reset to 0.00 automatically.
The volume unit only makes sense if the sensor has been calibrated for density measurement. Press
↵
to confirm and save the selection. Forward and reverse counters will now show the selected unit.
13.3.2 Reset
counters
To reset the totalizing counters, you definitely need to toggle to [yes]. Forward and reverse counters will
be reset at the same time (0.00).
Reset counters
[no]
According to the description in Section 12.4.3.1 Selection window/make a selection, one of the indicated
units can be selected. By pressing Esc or toggling to [no] the operator can cancel the current action with-
out changing the counter readings.
Page 58 of 106