Pl-1746-c04 module specifications, 3 specifications & factory defaults – Electro Cam PL-1746 Series User Manual

Page 136

Advertising
background image

9-3 Specifications & Factory Defaults

Output Specifications

Minimum

Typical

Maximum

Operating Voltage

20 V dc

24 V dc

30 V dc

Carry Current

1.5A dc

Leakage Current

150

µ

A dc

Turn-On Time

10

µ

s

50

µ

s

Turn-Off Time

20

µ

s

50

µ

s

Input Specifications

Minimum

Typical

Maximum

Absolute Maximum Voltage

30 V dc

Pickup Voltage

9.2 V dc

11.0 V dc

Dropout Voltage

7.0 V dc

9.2 V dc

Current Draw

3.5 mA dc

20 mA dc

PL-1746-C02/C03 Module Specifications (Cont'd)

On the -C02 ALL outputs are SOURCING, on the -C03 ALL outputs are SINKING.

PL-1746-C04 Module Specifications

Electrical (The PL-1746-C04 controller is UL and UL-C listed)

I/O Power:

20-30 VDC @ 80 mA plus 150 mA per PS-6400 keypad (include power supply warming).

Backplane Power:

5VDC @ 500 mA max.

Permanent Memory:

EEPROM (no battery required).

Environment

Operating Temp:

0

°

to 55

°

C (32

°

to 131

°

F).

Storage Temp:

-40

°

to 70

°

C (-40

°

to 160

°

F).

Humidity:

95% maximum relative non-condensing.

NEMA Rating:

Keypad/Display: NEMA 4

Physical

Weight:

PLS Module: 0.5 lbs (0.2 kg). Keypad/Display: 0.5 lbs. (0.2 kg).

Mounting

Controller:

Mounts in SLC-500 chassis.

Keypad/Display:

Mounts up to 1000' from controller. Multiple keypads may be connected to one controller.

Operation

Scan Time:

Less than 1000

µ

s typical (exact time determined by programming).

For faster response, interrupt-driven versions available—consult factory.

Position Resolution:

12 bits (4096 increments).

Speed Compensation:

Programmed in 0.1 msec steps. 16 individually compensated outputs max. Updated five times

per second. Separate leading/trailing edge compensation standard.

Output Timeout:

1.0 ms time base (accuracy: +1, -0 ms).

Number of Timed Outputs:

Four maximum.

Multiple Programs:

48 programs standard.

Total Pulse Memory:

1252 pulses standard.

Pulses per Program:

512 maximum standard.

Pulses per Output:

512 maximum standard.

Maximum Speed:

3000 RPM, Note: Pulses generated with Pulse Train command are not included in pulses per

program or pulses per output counts.

Advertising