Shift position, Shift register display, 41 pls functions – Electro Cam PL-1746 Series User Manual

Page 86

Advertising
background image

4-41 PLS Functions

Shift Position

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Shift Position

M0:S.917

1962

R/W

0 to (Scale Factor-1)

Screen

Menu Path

MAIN SCREEN

to FUNCTION MENU

to SHIFT POSITION

SHIFT POS: 350

Position at which Shift Register will shift.

Use INC and DEC, or the numeric keys and ENT.

Description

The Shift Position is the point in the encoder revolution at which the shift register data
shifts. Also see Shift Count and Shift Window.

Shift Register Display

Backplane

Reset the shift register by setting O:S.0/9.

Screens

MAIN SCREEN

to TEST MENU

to I/O STATUS MENU

SHIFT

REGISTER

127 SHFT-REG 064
0000000000000000

Shift register contents positions 64-127

191 SHFT-REG 128
0000000000000000

Shift register contents positions 128-191

255 SHFT-REG 192
0000000000000000

Shift register contents positions 192-255

063 SHFT-REG 000
0000000000000000

Shift register contents positions 0-63
16 hexidecimal digits

16 hexidecimal digits

16 hexidecimal digits

16 hexidecimal digits

All four parts of the Shift Register can be viewed by using the left/right arrow keys to
change to the next part. Note that the contents of the individual positions cannot be
changed.

Description

The Shift Register screen shows the current contents of the Shift Register. To reset all
positions in the Shift Register press the CLR key.

Advertising