Output groups, 20 pls functions – Electro Cam PL-1746 Series User Manual

Page 65

Advertising
background image

4-20 PLS Functions

Output Groups

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Group Quantity

M0:S.64

256

R/W*

1-6

Group Position Display

M0:S.65

258

R/W

0=EACH 1=ONE

Logic Inputs Status

M0:S.25

178

R/O

0-255

Group 0 Channel Count

M0:S.66

260

R/W*

0-32

Group 0 Mode

M0:S.82

292

R/W*

0-5

Group 0 Offset

M0:S.74

276

R/W

0 to (Scale Factor-1)

Group 0 Position

M0:S.16

160

R/W*

0 to (Scale Factor-1)

Group 1 Channel Count

M0:S.67

262

R/W*

0-32

Group 1 Mode

M0:S.83

294

R/W*

0-5

Group 1 Offset

M0:S.75

278

R/W

0 to (Scale Factor-1)

Group 1 Position

M0:S.17

162

R/W*

0 to (Scale Factor-1)

Group 2 Channel Count

M0:S.68

264

R/W*

0-32

Group 2 Mode

M0:S.84

296

R/W*

0-5

Group 2 Offset

M0:S.76

280

R/W

0 to (Scale Factor-1)

Group 2 Position

M0:S.18

164

R/W*

0 to (Scale Factor-1)

Group 3 Channel Count

M0:S.69

266

R/W*

0-32

Group 3 Mode

M0:S.85

298

R/W*

0-5

Group 3 Offset

M0:S.77

282

R/W

0 to (Scale Factor-1)

Group 3 Position

M0:S.19

166

R/W*

0 to (Scale Factor-1)

Group 4 Channel Count

M0:S.70

268

R/W*

0-32

Group 4 Mode

M0:S.86

300

R/W*

0-5

Group 4 Offset

M0:S.78

284

R/W

0 to (Scale Factor-1)

Group 4 Position

M0:S.20

168

R/W*

0 to (Scale Factor-1)

Group 5 Channel Count

M0:S.71

270

R/O

0-32

Group 5 Mode

M0:S.87

302

R/W*

0-5

Group 5 Offset

M0:S.79

286

R/W

0 to (Scale Factor-1)

Group 5 Position

M0:S.21

170

R/W*

0 to (Scale Factor-1)

*Not while
running

Screen

MAIN SCREEN

to CONFIG MENU

to INITIAL SETUP

to

OUTPUT GROUPS

Begin by moving the cursor to GRP QTY and entering the number of groups desired,
followed by ENT (or use the INC/DEC keys).

Next, move the cursor to GRP and enter “0” followed by ENT.

Move the cursor to CHNS and enter the number of output channels to be included in
Group 0, followed by ENT (or use the INC/DEC keys).

Move the cursor to MODE and enter the operating mode for the group from zero to five,
followed by ENT (or use the INC/DEC keys). See Section 6 for an explanation of the
operating characteristics of each mode.

Move the cursor back to GRP and repeat these steps for each group to be programmed.

When output channels are divided into groups, the appearance of the Main Screen will
change slightly. See MAIN SCREEN for details.

(continued)