4-19 PLS Functions

Output Enable ANDing

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Output Enable ANDing
Channels 0-31, 1bit/channel

M0:S.272-

672-

R/W

0=On

M0:S.273

674

1=Off

Screen

MAIN SCREEN

to CONFIG MENU

to INITIAL SETUP

to

OUTPUT ENABLE ANDING

Select a new channel by pressing INC/DEC, or using the numeric keys followed by
ENT. Use the SEL key to toggle ANDing on and off.

Description

Output Enable ANDing allows you to AND any output channels with the Output Enable
Signal. A channel ANDed with this signal will be enabled to turn on at its programmed
setpoints only while the Output Enable Signal is energized. The signal is the logical OR
of bit 7 in the register at address O.S.0 and PS-4108 rack input 7 (or dc input 7 on the
front panel of C02/C03 models). Note that if output word 0 is mapped to another regis-
ter, its value is ignored (set to zero) and the source for this signal is rack (dc input) input
7 alone.

Also see INPUT STATUS.

Output Assignment

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

C02,C03 only
Output Assignments

M0:S.600-

1328-

R/W*

0-31

Outputs 0-5, 1word/output

M0:S.605

1338

Not while
running

Screen

MAIN SCREEN

to CONFIG MENU

to INITIAL SETUP

OUTPUT

ASSIGN

OUTPUT: 0
CHANNEL: 0

To select the output to assign or the channel to use for that output, use the numeric
keys and ENT, or use the INC and DEC keys.

Description

The Output Assignment screen allows selection of any channel to drive each of the
front panel output terminals.