Output status, 23 pls functions – Electro Cam PL-1746 Series User Manual

Page 68

Advertising
background image

4-23 PLS Functions

Output Status

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Input Word 0

I:S.0

None

R/O

0=Off

PL-1746 Output Channel

1=On

0-15 Status, 1bit/channel

Input Word 1

I:S.1

None

R/O

0=Off

PL-1746 Output Channel

1=On

16-31 Status, 1bit/channel

Force Outputs On
Channels 0-31, 1bit/channel

M0:S.256-

640-

R/W

1=Force Active

M0:S.257

642

0=Force Inactive

Force Outputs Off
Channels 0-31, 1bit/channel

M0:S.264-

656-

R/W

1=Force Active

M0:S.265

658

0=Force Inactive

Screen

MAIN SCREEN

to TEST MENU

to I/O STATUS

to OUTPUT

STATUS

OUTPUTS 76543210
0-7< 00000000

Press the SEL key to change the set of outputs displayed.

Press

to access Output 0, causing the “0” to blink. Press

to turn this output on.

The “0” will change to a “1”. Select other desired outputs by pressing

or

. If the

output is already on, a “1” will be present instead of a “0”. So, the “1” will change to a “0”
when the output is forced.

Press

to return to output number selection. Outputs will remain forced until you

leave the Output Status screen.

Description

This screen shows the On/Off state of the output channels, and it allows the outputs to
be forced.

Setting a bit in one of the force outputs on registers will cause the corresponding output
to turn ON. Setting a bit in one of the force outputs OFF registers will cause the corre-
sponding output to turn OFF. Force OFF takes precedence over force ON. If outputs
are forced from the keyboard, the forcings are cleared when the status menu is exited
and the bits in these registers will be cleared.