Software version, Shift window (cont’d), 43 pls functions – Electro Cam PL-1746 Series User Manual

Page 88

Advertising
background image

4-43 PLS Functions

Software Version

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Base Revision

M0:S.4

136

R/O

0-32767

Major Revision

M0:S.3

134

R/O

0-32767

Screen

Menu Path

MAIN SCREEN

to TEST MENU

to SYSTEM INFO

to SOFT-

WARE VERSION

MAJOR REV:1.75
BASE REV:1.17

There are no values that can be changed in this screen.

Description

The Software Version screen displays the revision number of the firmware contained
within the controller. This information may be useful if the unit needs to be returned for
service.

Shift Window Overlaps Shift Position—Not Recommended!

When the Shift Window overlaps the shift position as
shown here, two problems may occur.

One Product, Two Bits: Due to variations in conditions,
sensors sometimes generate more than one pulse for a
product. If the product sensor sends a pulse early in the
window, that pulse will shift when the encoder reaches
the shift position. If the sensor sends a second pulse for
the same product after the shift position, a second bit will
be set for the same product.

Inconsistent Timing: Some products may appear early
in the Shift Window, while others appear late. For early
products, a bit will be set, then immediately shifted at the
shift position. For late products, a bit will be set after the
shift position, and a full revolution will occur before the bit
shifts to 1.

In most applications, programming Shift Window to
overlap the Shift Position will cause problems.

Shift Window

On at 900
Off at 100

0

500

First Bit Set

Shift Position

Second Bit Set

Shift Window (Cont’d)