Pulses used, Pulse copy (cont’d), 29 pls functions – Electro Cam PL-1746 Series User Manual

Page 74

Advertising
background image

4-29 PLS Functions

PROGRAM:---<

Program to add pulses to;
Enter number, then SEL to go to next screen

CHANNEL:---<

Channel to add pulses to;
Enter number, then SEL to go to next screen

ON: 0<

"On" time of leading edge of first pulse;
Enter 0, then ENT & SEL to go to next screen

OFF:950<

"Off" time of trailing edge of last pulse;
Enter 950, then ENT & SEL to go to next screen

COUNT 10<

Total number of pulses to be added;
Enter 10, then ENT & SEL to go to next screen

DURATION: 50<

Duration of each pulse added;
Enter 50, then ENT & SEL to go to next screen

DURATION: 50

EXECUTE<

Move cursor to EXECUTE, then press SEL to
generate pulses.

DURATION: 35

COMPLETE<

COMPLETE indicates pulses have been generated

<-P-> CH: 1 <EDG
ON: 0 OF: 50

Move cursor to OF and use arrow keys to
review pulse setpoints

Go to SETPOINTS to confirm the pulse train:

Pulses Used

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Pulses Total

M0:S.26

180

R/O

1252 Units without Shift Register
(no -S in model #)
787 Units with Shift Register
(-S in model #)

Pulses Used

M0:S.27

182

R/O

0 to Pulses Total

Screen

MAIN SCREEN

to TEST MENU

to SYSTEM INFO

to PULSES

USED

TOTAL: 1200
USED: 64

Total number of pulses available for programming
Number of pulses programmed into all channels
of all programs

Description

The number of pulses shown as "Used" is the sum of all pulses that are programmed
into all channels of all programs. The "Total" value is the number of pulses that can be
stored in non-volatile EEPROM memory. The difference between the two numbers is
the number of pulses available for programming. The number of pulses programmed
into all channels of all programs cannot exceed the value displayed as Total. There
are no values that can be changed in this screen.