Pulse copy, 27 pls functions – Electro Cam PL-1746 Series User Manual

Page 72

Advertising
background image

4-27 PLS Functions

Pulse Copy

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Pulse Copy Program

M0:S.704

1536

R/W

0-47

Pulse Copy Channel

M0:S.705

1538

R/W

0-31

Pulse Copy On (Train Start)

M0:S.706

1540

R/W

0 to (Scale Factor-1)

Pulse Copy Off (Train End)

M0:S.707

1542

R/W

0 to (Scale Factor-1)

Pulse Copy Count

M0:S.708

1544

R/W

1 to ((Off-On)/2)

(Number of Pulses)
Pulse Copy Duration (of each pulse) M0:S.709

1546

R/W

1 to ((Off-On)/2*Count)

Pulse Copy Command/Status

M0:S.710

1548

R/W*

Bit 15 Error

*Not while

Bit 14 Program Error

running

Bit 13 Channel Error
Bit 12 On > Scale Factor Error
Bit 11 Off > Scale Factor Error
Bit 10 Overlap Error
Bit 9 Duration Error
Bit 8 Reserved Bits Error
Bit 7-1 Reserved
Bit 0 Execute/Busy

M0:S.710/0

Execute Pulse Copy. This bit remains on until the copy is complete
or an error occurs. Either condition will clear this bit.

M0:S.710/1-7

Reserved bits. Writing a one to any of these bits will cause a reserved
bits error (see M0:S.710/8).

M0:S.710/8

Reserved bits. This bit is set if a one is written to any of the reserved
bits.

M0:S.710/9

The Duration Error bit is set if the pulse duration is < 1.

M0:S.710/10

The Overlap Error bit is set if the number of pulses created exceeds
one half the scale factor, which would cause pulses to be overlapped.

M0:S.710/11

The Off Pulse Copy value exceeds the scale factor.

M0:S.710/12

The On Pulse Copy value exceeds the scale factor.

M0:S.710/13

The channel error bit is set if channel value is out of range.

M0:S.710/14

The program error bit is set if program value is out of range.

M0:S.710/15

The Error bit is set if any of the above errors is set. This provides a
single bit to test for command success/failure. When the Error bit is
set, test the other bits to determine the exact cause.

When the error bit M0:S.710/15 is set, the Command Error bit and the Any Error bit
are set in the Progamming Error Register (I:S.7). To clear the error condition, toggle
Clear Error bit (O:S.0/8) ON. No additional commands will be accepted until the error
bits are cleared.

(continued)

Advertising