4-35 PLS Functions

Rate Setup

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Displayed Units

M0:S.51

230

R/W

0=RPM 1=BPM 2=CPM 3=IPM

Decimal Point Location

M0:S.52

232

R/W

0-3

Rate Multiplier

M0:S.53

234

R/W

1-1091

Rate Divisor

M0:S.54

236

R/W

1-63

Screen

Menu Path

MAIN SCREEN

to CONFIG MENU

to SECONDARY SETUP

to

RATE SETUP

MPY: 1< DP: 0
DIV: 1 RPM

Displayed Units

Rate Divisor

Decimal Point Location

Rate Multiplier

Units—Move the cursor to the “Units” field and use SEL to toggle between values.

MPY & DIV—Move the cursor to MPY or DIV and use the numeric keys followed by
ENT to enter a value.
DP—Move the cursor to DP and use SEL to toggle between values.

Following are a few examples of the relationships between multiplier (MPY), divider
(DIV), decimal points (DP), actual resolver speed, and displayed resolver speed:

If

And

And

Then

And a

Is

MPY

DIV

DP

MPY/DIV

Resolver

Displayed

Is…

Is…

Is…

Is…

Speed Of…

As…

1

2

0

.5

100 RPM

50 RPM

1

2

1

.5

100 RPM

5.0 RPM

1

2

2

.5

100 RPM

.50 RPM

1

2

3

.5

100 RPM

.050 RPM

1

1

0

1.0

100 RPM

100 RPM

1

1

1

1.0

100 RPM

10.0 RPM

1

1

2

1.0

100 RPM

1.00 RPM

1

1

3

1.0

100 RPM

.100 RPM

2

1

0

2.0

100 RPM

200 RPM

2

1

1

2.0

100 RPM

20.0 RPM

2

1

2

2.0

100 RPM

2.00 RPM

2

1

3

2.0

100 RPM

.200 RPM

Description

The Rate Setup function allows you to configure the RPM display on the Main Screen.