4-11 PLS Functions

Input Maps

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Input Word 0 Map #

M0:S.208

544

R/W

0-32767

Input Word 1 Map #

M0:S.209

546

R/W

0-32767

Input Word 2 Map #

M0:S.210

548

R/W

0-32767

Input Word 3 Map #

M0:S.211

550

R/W

0-32767

Input Word 4 Map #

M0:S.212

552

R/W

0-32767

Input Word 5 Map #

M0:S.213

554

R/W

0-32767

Input Word 6 Map #

M0:S.214

556

R/W

0-32767

Input Word 7 Map #

M0:S.215

558

R/W

0-32767

Screen

MAIN SCREEN

to MAPPING MENU

to INPUT MAP REGS

REG# INPUT MAP#

0

0

Use INC/DEC keys to select the desired mapping register. Use select, then the nu-
meric keypad, to enter the mapping index number followed by the ENT key. See the
section on Remote I/O and Register Mapping for more information. These registers
allow the user to select M0 or M01 file registers for reading through the eight Input file
registers.

Description

This screen displays the input mapping registers. When a mapping index number is
placed in one of these registers, the corresponding M0 or M1 register will be mapped
into the indicated input file register.

Input Status

Backplane

PL-1746 Function Name

SLC 500

Mapping Read/

Valid Range for Data

File

Index

Write

Address

Number

Capability

Output Word 0

O:S.0

None

W/O

Bit 16-10 Reserved

Logic Inputs

Bit 9 Clear Shift Register
(Models C02,C03 only)
Bit 8 Clear Error
Bit 7 Output Enable
Bit 6 First Cycle Enable
Bit 5 Group 5 Input
Bit 4 Group 4 Input
Bit 3 Group 3 Input
Bit 2 Group 2 Input
Bit 1 Group 1 Input
Bit 0 Group 0 Input

Logic Inputs Status

M0:S.25

178

R/O

0-255

Screen

MAIN SCREEN

to TEST MENU

to I/O STATUS

to INPUT

STATUS

(continued)

Advertising