Pulse copy (cont’d), 28 pls functions – Electro Cam PL-1746 Series User Manual

Page 73

Advertising
background image

4-28 PLS Functions

Pulse Copy (cont’d)

Example
Generate a train of pulses as follows:

Pulse

On

Off

1

0

50

2

100

150

3

200

250

4

300

350

5

400

450

6

500

550

7

600

650

8

700

750

9

800

850

10

900

950

Each pulse is 50 increments wide, separated from the next pulse by 50 increments.

Description

Pulse Copy allows you to program a series, or “train” of pulses into a channel without
having to enter the On and Off edges for each pulse. The Pulse Copy function prompts
you for the beginning and ending edges for the pulse train; the number of pulses in the
train; and the duration of a pulse. Pulse Copy then divides the designated portion of the
resolver cycle into the specified number of pulses, evenly dividing the unused portion of
the segment between the pulses.

Screens

Menu Path

MAIN SCREEN

to FUNCTION

to PULSE COPY

The Pulse Copy function consists of eight screens:

(continued)

PROGRAM:---<

Program to add pulses to;
Enter number, then SEL to go to next screen

CHANNEL:---<

Channel to add pulses to;
Enter number, then SEL to go to next screen

ON:---<

"On" time of leading edge of first pulse;
Enter number, then ENT & SEL to go to next screen

OFF:---<

"Off" time of trailing edge of last pulse;
Enter number, then ENT & SEL to go to next screen

COUNT---<

Total number of pulses to be added;
Enter number, then ENT & SEL to go to next screen

DURATION:---<

Duration of each pulse added;
Enter number, then ENT & SEL to go to next screen

DURATION: 35

EXECUTE<

Move cursor to EXECUTE, then press SEL to
generate pulses. To review values before executing,
move cursor to top row and press SEL as needed

DURATION: 35

COMPLETE<

COMPLETE indicates pulses have been generated

Advertising