2-19 Installation

DIP Switch Settings

Overview

Installation
Each PS-6400 keypad and PL-1746 module has a DIP switch. For convenience, set
these DIP switches before installing the keypads or module.

Termination Resistors
The PS-6400 keypad and PL-1746 PLS modules have built-in termination resistors for
the RS-485 network across which they communicate. The two devices at the physical
end of the RS-485 network must have their termination resistors connected; all de-
vices between them must have their termination resistors disconnected. The termina-
tion resistors are connected or disconnected by setting the appropriate DIP switches
on each device as indicated below.

PS-6400 Keypad DIP

Termination Resistors

Switch Settings

To connect the termination resistors, set switches 5 & 6 ON; to disconnect the
termination resistors, set switches 5 & 6 to OFF.

Address
Set switches 1-4 per the following chart to establish the desired address for the key-
pad. Keypad addresses must begin with 0 and increase sequentially. The physical
location of a keypad has no intrinsic relationship to its address. During initial program-
ming, the KEYBOARD QTY must be used to enter the number of keypads in the chain;
it can only be accessed through the keypad whose address is 0 or through the backplane.

Address

Switch 1 (B3) Switch 2 (B2) Switch 3 (B1) Switch 4 (B0)

0

ON

ON

ON

ON

1

ON

ON

ON

OFF

2

ON

ON

OFF

ON

3

ON

ON

OFF

OFF

4

ON

OFF

ON

ON

5

ON

OFF

ON

OFF

6

ON

OFF

OFF

ON

7

ON

OFF

OFF

OFF

8

OFF

ON

ON

ON

9

OFF

ON

ON

OFF

10

OFF

ON

OFF

ON

11

OFF

ON

OFF

OFF

12

OFF

OFF

ON

ON

13

OFF

OFF

ON

OFF

14

OFF

OFF

OFF

ON

15

OFF

OFF

OFF

OFF

PL-1746-C01 DIP Switch Settings (All reserved switches must be OFF)

Switch

ON

OFF

1

Local I/O Module

Remote I/O Module

2

Reserved

Reserved

3

Reserved

Reserved

4

Reserved

Reserved

5

Connect Termination Resistors Disconnect Termination Resistors

6

Reserved

Reserved

7

Reserved

Reserved

(continued)