Mount one of the PTO bearing covers (left or right) on the pump casing (pos. 1, fig. 67) and attach it with four

M8X30 screws (pos. 1, fig. 68).

Be careful of the direction of assembly of cover. The lubrication hole in the cover must

correspond to the hole in the casing.

Repeat the operations on the other side:

Insert the internal ring (pos. 1, fig. 61) and external ring (pos. 1, fig. 62) of the second bearing.

Mount the second PTO bearing on the pump casing (pos. 1, fig. 67) and attach it with 4 M8X30 screws (pos.

1, fig. 68).

Tighten the 4 screws with a torque wrench, as shown in section 3, “Screw Tightening Settings”.

Pre-assemble the two bearing covers:

Insert the bearing using a mallet or striking hammer (pos. 1, fig. 69) until 4 to 4.5 mm of the bearing is still

protruding, as shown in fig. 70