Page 40
Proceed to tighten the M16X150 screws with a torque wrench, as shown in section 3 “Screw Tightening
Settings”.
Tighten the 8 M16X150 screws, beginning by cross-tightening the 4 inside screws (see
fig. 135) and then moving on to the 4 outside screws, again, cross-tightening them.
Tighten the M16X55 screws of the cover with a torque wrench, as shown in section 3, “Screw Tightening
Settings”.
Insert the valve lifters (pos. 1, fig. 136) and screw them in using a 30 mm spanner (pos. 1, fig. 137).