Lk series – General Pump LK Repair Manual User Manual

Page 38

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

LK SERIES

Page 38

Be very careful when inserting the O-ring indicated in pos. 1, fig. 128. We recommend

using the special tool, p/n F27516000 (for LK36, 40, 45) or p/n F27516100 (for LK50, 55,

60), to prevent the O-ring from being cut during insertion.

Insert the valve seat ring (pos. 1, fig. 129 and the spring (pos. 1, fig. 130).

Insert the O-ring, exploded position #17 (pos. 1, fig. 127)

Advertising