Lk series, General pump, Screw calibration – General Pump LK Repair Manual User Manual

Page 48

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

LK SERIES

Page 48

3. SCREW CALIBRATION

Screws are to be fastened exclusively using a torque wrench.

Description

Exploded View

Position

(From Owner’s Manual)

Fastening

Ft. Lbs.

Fastening

Nm

M8x20 screw, casing cover

42

18.44

25

G1/2x13 plug, casing

66

29.5

40

M8x30 screw, PTO bearing cover

85

18.44

25

M8x20 screw, shaft end cover

42

18.44

25

M10x30 screw, bearing support cover

57

33.2

45

M6x14 screw, upper & lower covers

70

7.38

10

M8x20 screw, bearing cover

42

18.44

25

M12x1.25x87 screw, connecting rod

tightening

40

55.32

75*

M10x35 screw, plunger head

38

44.25

60

M12x25 screw, bushing locking flange

51

50.52

68.5

M10x160 screw, plunger attachment

27

29.5

40

M16x55 screw, valve cover

26

245.6

333

G1/4”x13 screw, head

13

29.5

40

M16x150 screw, head

25

245.6

333**

Valve lifter

2

29.5

40

* Reach the tightening torque by tightening the screws simultaneously.

** Tightening sequence always cross-wise starting from the 4 internal screws (see fig.

135) then the 4 external screws.

Advertising