Lk series – General Pump LK Repair Manual User Manual

Page 45

Advertising
background image

GENERAL PUMP

A member of the Interpump Group

LK SERIES

Page 45

Screw the gasket support to the liner (pos. 1, fig. 154) and tighten using a compass spanner with Ø 5 round

ends, available on the market (pos. 1, fig. 155), until the support abuts the liner.

Place the 14x2 O-ring on its seat on the plunger attachment screw (pos. 1, fig. 156).

Place the plungers on their respective holders (pos. 1, fig. 157) and fix them in place as in pos. 1, fig. 158.

Advertising