Remove the inlet valve assembly by using a slide hammer puller applied to the M10 hole in the valve holder

(pos. 1, fig. 112).

Remove the inlet and outlet valve assemblies by screwing in an M10 screw so as to attach it to the inside

holder and take out the valve holder from the valve seat (pos. 1, fig. 114).

If it is particularly difficult to remove the outlet valve assembly (e.g. there are build up

deposits because the pump has not been used for a long period), use the extractor tool

F27516200 (for LK36,40,45) or p/n 27516300 (for LK50, 55, 60) (pos. 1, figs 113) and

use it as shown in the diagram.