Repeat the operation on the other side.

Remove the M16 screw from the crankshaft. Screw the two bushing locking flanges onto the crankshaft using

4 M12X25 screws (pos. 1, fig. 87).

Apply LOCTITE 243 to the threads of the M12X25 screws (pos. 1, fig. 87).

Tighten the screws with a torque wrench, as shown in section 3, “Screw Tightening Settings”.

Remove the anti-rotation shim from under the shank of the central connecting rod.

Mount the two bearing covers (with their O-rings) (pos. 1, fig. 89) using 6 M8X20 screws (pos. 1, fig. 90).

Tighten the screws with a torque wrench, as shown in section 3, “Screw Tightening Settings”.