IAI America XSEL-S User Manual
Page 113
Chapter 2 Wiring
2.2.10 Extension I/O unit (Option)
105
No.
Parameter name
Set in
Delivery
Set
Value
Details of Parameters
4000+n (Multiples of 16)
When it is not to be used, set it to “-1”.
Set the address following to the slot No.1’s
input address.
Set Value = (Slot No. 1’s Input Address) +
(No. of Inputs of the Slot No. 1)(Example)
Slot 1
Top Address
Slot 11
Number of Input Points
4000
16
points
32
points
48
points
710 Extension output Port Start Number at
Extension I/O Unit Slot 2 Fixed Assignment
-1
Refer
to the
Right
Box.
Set Value
4032
4016
4048
711 Extension input Port Start Number at
Extension I/O Unit Slot 3 Fixed Assignment
-1
Refer
to the
Right
Box.
1000+n (Multiples of 16)
When it is not to be used, set it to “-1”.
Set the address following to the slot No.2’s
input address.
Set Value = (Slot No. 2’s Input Address) +
(No. of Inputs of the Slot No. 2)(Example)
712 Extension output Port Start Number at
Extension I/O Unit Slot 3 Fixed Assignment
-1
Refer
to the
Right
Box.
4000+n (Multiples of 16)
When it is not to be used, set it to “-1”.
Set the address following to the slot No.2’s
input address.
Set Value = (Slot No. 2’s Input Address) +
(No. of Inputs of the Slot No. 3)(Example)
713 Extension input Port Start Number at
Extension I/O Unit Slot 4 Fixed Assignment
-1
Refer
to the
Right
Box.
1000+n (Multiples of 16)
When it is not to be used, set it to “-1”.
Set the address following to the slot No.3’s
input address.
Set Value = (Slot No. 3’s Input Address) +
(No. of Inputs of the Slot No. 3)(Example)
714 Extension output Port Start Number at
Extension I/O Unit Slot 4 Fixed Assignment
-1
Refer
to the
Right
Box.
4000+n (Multiples of 16)
When it is not to be used, set it to “-1”.
Set the address following to the slot No.3’s
input address.
Set Value = (Slot No. 3’s Input Address) +
(No. of Inputs of the Slot No. 3)(Example)