Troubleshooting

7.3 Error List (MAIN application)

428

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

56A CC-Link system domain use error CC-Link system domain cannot be used as the system

input and output port of X-SEL. It can be considered as the

cause that CC-Link system domain is used as a system

output as shown below. Check the I/O parameter settings.

1) Input and output function select port number

2) Zone output port number

3) Simple interference check zone output port number

4) Vision system I/F capturing command physical output

port number

5) Tracking vision system capturing command physical

output port number

6) Pulse input and output board control output port number

601 EMG logic error

There is a concern of pin bending breakage inside the

controller.

602 ENB logic error

There is a concern of pin bending breakage inside the

controller.

603 Drive-source cutoff relay DET

(MELT) error

The drive-source cutoff relay may have fused.

604 Power-supply board CPU ready

OFF error

A ready status of the power-supply board cannot be

confirmed.

605 Forced discharge error

Abnormal forced discharge. The drive-source cutoff relay

may be abnormal.

The power must be reconnected.

606 Regenerative discharge error

Abnormal regenerative discharge.

The power must be reconnected.

607 Motor power-source voltage low

error

Low voltage was detected in the motor power circuit.

608 Power-supply board

FRCDCSTR-ON timeout error

Power-supply board FRCDCSTR-ON could not be

confirmed within the specified time.

609 Power-supply board

RBONSTR-ON timeout error

Power-supply board RBONSTR-ON could not be confirmed

within the specified time.

60A Power-supply board

RBONSTR-OFF timeout error

Power-supply board RBONSTR-OFF could not be

confirmed within the specified time.

60B Power-supply board

FRCDCSTR-OFF timeout error

Power-supply board FRCDCSTR-OFF could not be

confirmed within the specified time.

60C Power-system overheat error

An overheated power-supply board, regenerative resistor,

etc., was detected.

The power must be reconnected.

60D Slave board CPU ready OFF error

(other than power supply)

A ready status of the driver board, etc. (other than

power-supply board) cannot be confirmed.

60E Dynamic brake ON/OFF timeout

error

Dynamic brake ON/OFF cannot be confirmed within the

specified time.

60F Power-supply board synchronous

send timing error 1 (CPSDBSYER)

A communication failure occurred between the

power-supply board and FPGA (main).

610 Power-supply board synchronous

send timing error 2 (CPCLKER)

A communication failure occurred between the

power-supply board and FPGA (main).

611

Power-supply board synchronous

communication LRC error

A communication failure occurred between the

power-supply board and FPGA (main).

612 Power-supply board synchronous

communication timeout error

A communication failure occurred between the

power-supply board and FPGA (main).

613 Driver synchronous communication

driver read error

A communication failure occurred between the driver board

and FPGA (main).

Cold-st

art

lev

el

errors

614 Driver synchronous communication

LRC error

A communication failure occurred between the driver board

and FPGA (main).