Advertising
background image

Chapter 6 Parameter

6.3.2 For XSEL-RX/SX, RXD/SXD

357

Axis-Specific Parameters (XSEL-RX/SX, RXD/SXD)

No.

Parameter name

Default value

(reference)

Input range

Unit

Remarks

No.

11

ABS Reset Position

Movement /

Home-Return End

Search Direction Select

0

0

0 to 1

0: Coordinate negative end

1: Coordinate positive end

12 Home preset value

90000,

0,

0,

-90000

0

-99999999

to

99999999

0.001mm

0.001deg

13

SIO�PIO ABS Reset

Position Movement /

Home-Return Order

0

0

0 to 16

Executed from smaller

14 Home position check

sensor input polarity

0

0

0 to 2

0: Unused, 1: Contact a, 2: Contact b

15 Overrun Sensor Input

Polarity

0

0

0 to 2

0: Unused, 1: Contact a, 2: Contact b

16 Creep Sensor Input

Polarity

0

0

0 to 2

0: Unused, 1: Contact a, 2: Contact b

17

ABS Reset Position

Movement / Initial Home

Sensor Escape Velocity

in Home-Return

10

10

1 to 100

mm/sec

18

ABS Reset Position

Movement / Creep

Velocity in Home-Return

100

100

1 to 500

mm/sec

End search velocity in creep sensor

non-detecting area when using creep

sensor

19

ABS Reset Position

Movement / End Search

Velocity in Home-Return

3,

3,

20,

10

20

1 to 100

mm/sec

20

ABS Reset Position

Movement / Z-Phase

Search Velocity in

Home-Return

3

3

1 to 10

mm/sec

Attention needed due to limitations caused

by number of lead encoder pulses

21

ABS Reset Position

Movement / Offset

Movement in

Home-Return

0

1000

-99999999

to

99999999

0.001mm

Offset movement amount from the

Z-phase ideal position

(Positive value = direction to go against

the end) (Refer to Each Axis Parameter

No. 76.)

* Caution for ABS Encoder

There is a concern that the coordinate

may get misaligned for the amount of a

Z-phase pulse because it gets to the

servo lock condition on the Z-phase at

ABS reset if a value around multiples of

a Z-phase distance integer (including

offset movement amount 0) is set in this

parameter.

Do not attempt to set a value around

multiples of a Z-phase distance integer.

(Have an enough margin to the

amplitude of the servo system.)

* Set 0 for the wrist axis

22 Z-Phase Position Error

Check Allowable

1000,

1000,

500,

1000

500

0 to

99999999

0.001mm

0.001deg

[SCARA axis]

[Search end (Z-axis (Zc)) or datum

posture (eye mark) (Arm 1 Axis (A1c),

Alarm 2 Axis (A2c), R-axis (Rc))] –

Z-phase actual distance (angle) minimum

allowable

[linear sliding axis]

Minimum allowable actual distance

between an end (mech side or LS) and

Z-phase when rotary encoder

Z-phase search limit when linear encoder

23 Number of Z-Phase in 1

Turn of Encoder

1

1

1 to 8

Only 1 is available to use when ABS

encoder. It is invalid when linear encoder