Chapter 6 Parameter

6.10 Parameter Setting (Applied)

398

I/O Parameter Settings (Reference)

No.

Parameter name

Default value

Input range

Unit

201 Attribute 1 of SIO channel 1 opened to user (standard mount)

28100001H

0H to FFFFFFFFH

None

213 Attribute 1 of SIO channel 2 opened to user (standard mount)

28100001H

0H to FFFFFFFFH

None

Bits 28 to 31: Baud rate type (0: 9.6, 1: 19.2, 2: 38.4, 3: 57.6, 4: 76.8, 5: 115.2 kbps)

Bits 24 to 27: Data length (7: 7 bit, 8: 8 bit)

Bits 20 to 23: Stop bit length (1: 1 bit, 2: 2 bit)

Bits 16 to 19: Parity type (0: None, 1: Odd, 2: Even)

Bits 12 to 15: Reserved by the system

Bits 8 to 11: Reserved by the system

Bits 4 to 7:

Reserved by the system

Bits 0 to 3:

Use selection (0: Do not use, 1: Use)

No.

Parameter name

Default value

Input range

Unit

202 Attribute 2 of SIO channel 1 opened to user (standard mount)

00000001H

0H to FFFFFFFFH

None

214 Attribute 2 of SIO channel 2 opened to user (standard mount)

00000001H

0H to FFFFFFFFH

None

Settings

Bits 28 to 31: Reserved by the system

Bits 24 to 27: Reserved by the system

Bits 20 to 23: Reserved by the system

Bits 16 to 19: Character transmission interval (msec)

Bits 12 to 15: Communication method (0: Full duplex, 1: Half duplex)

Bits 8 to 11:

Send operation type in half duplex communication

(0: Do not check CTS-ON when sending,

1: Check CTS-ON when sending)

Bits 0 to 7:

Minimum receive �

send delay time in half duplex communication (msec)

No.

Parameter name

Default value

Input range

Unit

203 Attribute 3 of SIO channel 1 opened to user (standard mount)

01118040H

0H to FFFFFFFFH

None

215 Attribute 3 of SIO channel 2 opened to user (standard mount)

01118040H

0H to FFFFFFFFH

None

Settings

Bits 28 to 31: Flow control type

(0: None, 1: Xon/Xoff, 2: Hardware)

* This setting is valid in full duplex communication.

* If flow control is performed, select 38.4 kbps or lower. If the baud rate is

higher, an overrun error, etc., may occur.

Bits 24 to 27: Xon send selection when sending after SIO-CPU reset is enabled

(0: Do not send, 1: Send)

* This setting is valid in full duplex communication and only when Xon/Xoff

flow control is performed.

Baud rate 0: 9.6 kbps 1: 19.2 kbps

2: 38.4 kbps 3: 57.6 kbps 4: 76.8 kbps 5: 115.2 kbps

Data length 7, 8
Stop bit length 1, 2

Parity type 0: None, 1: Odd, 2: Even

Reserved by the system

Reserved by the system

Reserved by the system

Use selection (0: Do not use, 1: Use)