IAI America XSEL-S User Manual

Page 428

Advertising
background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

420

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

47B Slave communication error

There was an error generated in the slave communication

process. If a communication related error is occurred on

other slaves at the same time on the error list, it is

concerned a communication problem due to noise,

short-circuit or circuit problem.

Check the slave card.

47C Extension motion control board

synchronized operation axis setting

error

There is a mistake in the axis setting for the extension

motion control board synchronizing process.

If a setting is established to have the synchronized

electronic cam and the master axis of the electronic shaft

synchronizing operation as the slave axes, an axes setting

that the relation of slave axis -> master axis is closed in a

loop cannot be made.

47D Slave driver home-return complete

signal cutoff error

It was detected the home-return complete signal is turned

off for the slave driver (SCON, ACON, PCON, etc.)

controlled by the extension motion control board.

Check on such problems as cable breakage on the pulse

input and output board.

47E Extension motion control board

input channel synchronizing start

error during counter clear

Synchronizing process was tried to start while the counter

clear was executed when the master axis is an extension

motion control board input channel.

47F Extension motion control board

synchronized axis error detection

There was an error occurred between the axes in a

synchronizing relation while the extension motion control

board is in synchronizing process.

Check if any error is generated on the slave axes, master

axis, axes that are operated by the commands same as

the master axis or the slave axes that are connected by

synchronization below them.

491 IA Net stop detection error at IAI

protocol transfer�

IA Net is not working properly during the IAI protocol

transfer in IA Net.

Confirm that the IA Net board is mounted in the

appropriate way or the IA Net is working properly.�

492 IA Net IAI protocol mail sending

error�

IAI protocol communication failed in IA Net.

Check the condition of IA Net connection, communication

station number, I/O parameters No. 602 to 605, etc.�

496 Extension motion control board

coordinate system data change

forbidden error during axis

operation

A change cannot be made in the coordinate system data

while an extension motion control board axis is in

operation.

* for SCARA only�

497 Servo slave operation command

velocity excess error

The command from the slave operation command issuer

unit has exceeded the maximum velocity.

For a pulse input and output board slave operation, make

sure the setting Pulse input and output board output

channel parameter No. 12 does not exceed the values in

each axis parameter No. 27 and 28.

498 Servo slave operation command

issuer stop confirmation timeout

error

Confirmation cannot be made on the stop of the slave

operation command.

49A Extension motion control board

command pulse counter excess

error

The value on the counter of the command pulse input

channel exceeded the range between -2,147,482,624 and

2,147,482,623 during synchronizing process.

If the input channel is set as the synchro-master axis, use

the product with the input pulse in the range described

above.

O

pe

ra

tio

n-

ca

nc

el

la

tio

n

le

ve

l e

rro

rs

49B SEL program source symbol

management domain sum check

error

SEL program is destroyed.

Initialize the SEL program.