Chapter 6 Parameter

6.2.2 For XSEL-RX/SX, RXD/SXD

341

Parameters Common to All Axes (XSEL-RX/SX, RXD/SXD)

No.

Parameter name

Default

value

(reference)

Input range

Unit

Remarks

130 Reserved by the system

(change is prohibited)

0

131 Reserved by the system

(change is prohibited)

0

132

SCARA Tip Load Max.

Transportable Weight

(1

st

to 4

th

Axis)

10000

1 to

99999999

g

133

SCARA Tip Load Max.

Allowable Moment of Inertia

(1

st

to 4

th

Axis)

60000

1 to

99999999

kgmm

2

134 Reserved by the system

(change is prohibited)

0

0 to 5

135 Reserved by the system

(change is prohibited)

0

0 to 999

136 SCARA Function information 1

(1

st

to 4

th

Axis)

0H

0H to

FFFFFFFFH

137

SCARA Tip Load Rated

Transportable Weight

(1

st

to 4

th

Axis)

0

0 to

99999999

g

Invalid when set to 0.

138 (For expansion)

0

to

139 Reserved by the system

(change is prohibited)

50891

140 Reserved by the system

(change is prohibited)

98000

141 Reserved by the system

(change is prohibited)

0

142 Reserved by the system

(change is prohibited)

0

143 Reserved by the system

(change is prohibited)

0

144 Reserved by the system

(change is prohibited)

0

145 Reserved by the system

(change is prohibited)

0

146 Reserved by the system

(change is prohibited)

0

147 Reserved by the system

(change is prohibited)

0

148 Reserved by the system

(change is prohibited)

0

149 Reserved by the system

(change is prohibited)

0

150 Reserved by the system

(change is prohibited)

0

151

to

199

(For expansion)

0

200 Linear Sliding Axis

Acceleration Initial Setting

30

1 to 200

0.01G

Used when not indicated in position data,

program or SIO message

Note: Valid only on linear sliding axes

201 Linear Sliding Axis

Deceleration Initial Setting

30

1 to 200

0.01G

Used when not indicated in position data,

program or SIO message

Note: Valid only on linear sliding axes

202 Linear Sliding Axis Speed

Initial Setting

30

1 to 250

mm/s

Used in continuous recovery movement when

SIO message and position data not indicated

Note: Valid only on linear sliding axes

203 Linear Sliding Axis Max.

Acceleration

100

1 to 999

0.01G

Restriction is made for each axis with the setting

values above if Each Axis Parameter No. 134

“Maximum Operation Acceleration for Each Axis”

is valid.

Note: Valid only on linear sliding axes