IAI America XSEL-S User Manual

Page 190

Advertising
background image

Chapter 4

Absolute Reset and

Absolute Battery

4.1.1 For PC Software

182

[When performing Push Stopper Type Absolute Reset on Each Axis One by One]

To have the push stopper type absolute reset for each axis one by one, follow the steps

shown below.

1

st

Arm and 2

nd

Arm

1) Select “Individual axis” in the push type absolute reset window, and set Axis to “Arm 1” (or

Arm 2).

2) Click “Encoder Rotation Data Reset / Reset Controller Error (Step 1/4)”.

3) In case there is a concern that a load may interfere with surroundings at the absolute reset,

detach the load. Have the work during the emergency stop condition. After the work is

finished, click on the “OK” button.