IAI America XSEL-S User Manual

Page 453

Advertising
background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

445

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

B00 SCHA setting error

The setting of SCHA command is invalid.

B01 TPCD setting error

The setting of TPCD command is invalid.

B02 SLEN setting error

The setting of SLEN command is invalid.

B03 Home-return method error

The setting of “Axis-specific parameter No. 10,

Home-return method” is invalid. (Not incremental encoder

AND current position 0 home is specified, etc.)

B04 1-shot-pulse output excessive

simultaneous use error

The number of BTPN and BTPF timers operating in one

program simultaneously exceeds the upper limit (16).

B05 Estimate-stroke over error at home

return

The operation at home return exceeded the estimate

stroke. The home sensor or creep sensor may be faulty,

among other reasons.

B06 Expanded-SIO in-use error

An attempt was made to open a channel already opened

by other task.

B07 Expanded-SIO unopen error

An attempt was made to use a channel not opened by own

task.

B08 Expanded-SIO duplicate WRIT

execution error

WRIT commands were executed simultaneously by

multiple tasks for the same channel.

B09 Expanded-SIO RS485

WRIT/READ simultaneous

execution error

WRIT and READ commands were executed

simultaneously in the RS485 mode.

B0A Expanded-SIO

unassigned-channel use error

An attempt was made to use a channel not assigned

properly.

Check I/O parameter Nos. 100 to 111 and the statuses of

I/O slots.

B0B Pressing release WAIT timeout

error

Pressing time has passed the allowable limit without a

command for pressing release from the host system during

the stopper pressing position acquirement or pressing

operation at stopper pressing method absolute reset.

It is concerned that the connection of the PC software may

be cut due to a communication failure.

Reconnect the PC software and restart the process from

the first step.

B0C Pressing release movement

condition non-established error

The unit is in a condition that the pressing release

movement cannot be performed during the stopper

pressing position acquirement or pressing operation at

stopper pressing method absolute reset.

Pressing operation is cancelled due to such reasons as an

error generation or emergency stop.

Restart the process from the first step.

B0D Stopper pressing movement start

position error

The start position for stopper pressing movement is too

close to the stopper during the stopper pressing position

acquirement or pressing operation at stopper pressing

method absolute reset. Put the start position further from

the stopper and try again.

B10 Z-phase search timeout error

Z-phase cannot be detected.

Check items such as the operation restrain, wiring, motor

or home sensor.

B11 Home sensor escape timeout error

The escape from the home sensor has not been

confirmed within the specified time period.

Check the stuck, wiring, motor or home sensor, etc.

B12 SEL command return dome

storage variable number error

SEL command return dome storage variable number error

B15 Input port debug filter type error

There is an error in the input port debug filter type setting.

O

pe

ra

tio

n-

ca

nc

el

la

tio

n

le

ve

l e

rro

rs

B16 SEL operand indication error

There is an error in the SEL command language operand

indication.

Advertising
This manual is related to the following products: