Watlow EZ-ZONE ST User Manual

Page 18

Advertising
background image

Watlow EZ-ZONE

®

ST

16

Chapter 2 Install and Wire

Replacing the Solid-State Relay

on a Controller with a Contactor

(ST _ _ - (B or F) _ _ _ - _ _ _ _)

1. Pinch the release levers on the top and

bottom of the control module and lift the

right edge forward to detach the unit.

2. With a Phillips screwdriver, remove

the four nearest screws that were under

the module.

4. Lift the controller body, exposing

the solid-state relay.

5. Using a Phillips screwdriver, remove

the two screws connecting the solid-

state relay to the heat sink.

3. With a Phillips screwdriver, remove

the two screws at the top corners of the

controller.

Replacing the Solid-state Relay
1. Using a Phillips screwdriver, replace

the two screws connecting the solid-

state relay to the heat sink. Check that

the bottom of the solid-state relay is on

the left.
2. Place the controller body over the

solid-state relay and, using a Phillips

screwdriver, replace the six screw se-

curing it.
3. Snap the control module in place,

left edge first.

Note:

For controller models with a contactor (ST _ _-A _ _ _-_ _ _ _), the

solid-state relay must be mounted with the larger power terminals on

the right and the smaller control terminals on the left .

Advertising