Chapter 4: setup pages, Control module setup page parameters – Watlow EZ-ZONE ST User Manual

Page 41

Advertising
background image

Watlow EZ-ZONE

®

ST

39

Chapter 4 Setup Page

Chapter 4: Setup Pages

Control Module Setup Page Parameters

4

[``Ai]
[`Set]

Analog Input Menu

[```1]
[``Ai]

Analog Input 1 (to 2)

[`SEn] Sensor Type

[`Lin] Linearization

[`rt;L] RTD Leads

[Unit] Units

[`S;Lo] Scale Low

[`S;hi] Scale High

[`r;Lo] Range Low

[`r;hi] Range High

[`P;EE] Process Error Enable

[`P;EL] Process Error Low

[`FiL] Filter

[`i;er] Error Latching

[`dEC] Display Precision

[`s;ba] Sensor Backup

[`dio]
[`Set]

Digital Input/Output Menu

[```1]
[`dio]

Digital Input/Output 5 (to 6)

[`dir]

Direction

[``Fn]

Output Function

[``Fi]

Function Instance

[`o;Ct] Control
[`o;tb]

Time Base

[`LEu] Active Level

[``Fn] Action Function
[``Fi]

Function Instance

[LiM]
[`Set]

Limit Menu

[```1]
[LiM]

Limit 1

[`L;SD]

Sides

[`L;hy] Hysteresis
[SP;Lh]

Set Point Limit High

[SP;LL]

Set Point Limit Low

[`L;it] Limit Integrate

[Loop]
[`Set]

Control Loop Menu

[```1]
[Loop]

Control Loop 1

[`h;Ag]

Heat Algorithm

[`C;Ag]

Cool Algorithm

[t;tUn]

Tru-Tune+

®

Enable

[t;bnd]

Tru-Tune+ Band

[`t;gn]

Gain

[t;Agr]

Autotune Aggressiveness

[`P;dl] Peltier Delay

[`UFA] User Failure Action

[FAiL] Input Error Failure

[MAn] Manual Power

[`L;dE] Open Loop Detect Enable
[`L;dt]

Open Loop Detect Time

[`L;dd]

Open Loop Detect Deviation

[``rp] Ramp Action
[`r;SC]

Ramp Scale

[`r;rt]

Ramp Rate

[`L;SP] Set Point Closed Limit Low
[`h;SP]

Set Point Closed Limit High

[SP;Lo]

Set Point Open Limit Low

[SP;hi]

Set Point Open Limit High

[otpt]
[`Set]

Output Menu

[```1]
[otpt]

Output 1 (to 4)

[``Fn]

Output (2 to 4) Function

[``Fi]

Function Instance

[`o;Ct]

Control

[`o;tb]

Time Base

[`o;Lo]

Low Power Scale

[`o;hi]

High Power Scale

[``Fn] Output (1) Function

[ss;ti]

Soft Start Time

[ALM]
[`Set]

Alarm Menu

[```1]
[ALM]

Alarm 1 (to 2)

[`A;ty]

Type

[`sr;a] Source
[`is;a]

Instance

[`A;hy]

Hysteresis

[`a;Lg]

Logic

[`A;SD]

Sides

[`a;LA]

Latching

[`A;bL]

Blocking

[`a;Si]

Silencing

[A;dsp]

Display

[`A;dL]

Delay

[CUrr]
[`Set]

Current Menu

[```1]
[CUrr]

Current 1 (to 4)

[`C;Sd]

Sides

[`C;Ur]

Read Enable

[`C;le]

Limit Enable

[`C;dt]

Detection Threshold

[C;ofs]

Heater Current Offset

[`fUn]
[`Set]

Function Key Menu

[```1] to [```2]
[`fUn]

Function Key

[``Fn] Event Function
[``fi]

Function Instance

[gLbL]
[`Set]

Global Menu

[```1]
[gLbl]

Global

[`C_F]

Display Units

[AC;LF]

AC Line Frequency

[p;typ] Profile Start Type
[`gse]

Guaranteed Soak Enable

[gsd1] Guaranteed Soak Deviation

[d;prs] Display Pairs
[USr;S]

User Settings Save

[USr;r] User Settings Restore

[COM]
[`Set]

Communications Menu

[```1]
[COM]

Communications

[ad;m] Modbus Address
[bAUd]

Baud Rate

[`PAr]

Parity

[M;hL]

Modbus Word Order

[`C_F] Display Units

[map] Data Map

[`nu;s] Non-Volatile Save

To go to the Setup Page from the

Home Page, press both the Up ¿

and Down ¯ keys for six seconds.
[``Ai]

will appear in the upper

display and [`Set] will appear in

the lower display.

• Press the Up ¿ or Down ¯

key to view available menus.

On the following pages top

level menus are identified with

a yellow background color.

• Press the Advance Key

to

enter the menu of choice.

• If a submenu exists (more than

one instance), press the Up ¿

or Down ¯ key to select and

then press the Advance Key

to enter.

• Press the Up ¿ or Down ¯

key to move through available

menu prompts.

• Press the Infinity Key ˆ to

move backwards through the

levels: parameter to submenu;

submenu to menu; menu to

Home Page.

Press and hold the Infinity

Key ˆ for two seconds to re-

turn to the Home Page.

Advertising