Chapter 1: overview, The ez-zone, St provides total thermal system control – Watlow EZ-ZONE ST User Manual

Page 5: St provides total ther- mal system control, Features and benefits

Advertising
background image

Watlow EZ-ZONE

®

ST

3

Chapter 1 Overview

Chapter 1: Overview

1

The EZ-ZONE

®

ST Provides Total Ther-

mal System Control

The EZ-ZONE ST solid-state controller offers com-

plete thermal system control in a single package

while reducing system complexity and the cost of

control-loop ownership. You can order a PID control-

ler already connected to a high-amperage, solid-state

relay capable of zero cross or phase angle firing with

the option of adding a properly sized heat sink, an

over-under temperature limit, a shut-down power

contactor, and digital communications in one package.
It just got a whole lot easier to solve the thermal

requirements of your system. Because the EZ-ZONE

ST along with the entire family of EZ-ZONE controls

are highly scalable where you pay only for what you

need. So if you are looking for a PID controller with

high amperage outputs, an over-under limit controller

or an integrated controller, the EZ-ZONE ST is the

answer.

Features and Benefits

Back panel or DIN rail mount
• Provides several mounting options
Compact package
• Reduces panel size
Touch-safe package
• IP2X-Touch safe with back of hand

• Increases safety for installers and operators
±0.1 percent temperature accuracy
• Provides efficient and accurate temperature control
Agency approvals:

(with factory-installed

heatsink);

(without factory-installed heat-

sink); CE; RoHS; W.E.E.E.; CSA
• Limit version features FM approval

• Provides third-party recognition
Three-year warranty
• Provides Watlow reliability and product support
Off-the-shelf designed system solution
• Improves system reliability and reduces wiring

• Reduces installation cost

• Eliminates compatibility headaches often encoun-

tered when using many different components and

brands
Profile capability
• Includes ramp and soak with four files and forty

steps

Communications with PLC, PC or HMI
• ST with optional Modbus

®

RTU protocol

• When used with the optional Remote User Inter

face/Gateway (RUI/GTW) the following protocols

are available:
- EIA 232/485 Modbus RTU
- Modbus TCP
- EtherNet/IP
- DeviceNet
- Profibus DP
Solid-State Relay output
• Provides faster cycling, more precise control, in-

creased heater life and energy efficiency
• Resistive or inductive load current of up to 75 am-

peres using either zero-cross or phase angle control

modes
• Soft start feature with phase angle control mode to

prevent load failure or blowing fuses
PID temperature control
• Provides accurate temperature control

• Provides a single input and dual outputs

• Provides standard or adaptive (TRU-TUNE+)

PID tuning algorithms.
Optional temperature limit
• Increases safety during under and over-tempera-

ture conditions
Optional definite purpose mechanical contactor
• Enables circuit safety shutdown driven by a limit

controller or a PID alarm output signal
Optional current monitoring feature

• Detects heater current flow and alarm indication of

failed Solid-State Relay or a heater zone
Optional Solid-State Relay heat sink
• Sized and engineered for specific applications

• Factory assembled heat sink required for UL listing
System diagnostics
• Provides continuous system level monitoring with

alerts reducing the overall cost for maintenance ad

service
Advanced controllability algorithms
• TRU-TUNE+™ meets demanding controllability

requirements.
PC Software: EZ-ZONE ST Configurator
• Wizard-style configuration of controller settings

• Online or offline recipe editing

UL® is a registered trademark of Underwriter’s Laboratories Inc.
Modbus™ is a trademark of Schneider Automation Incorporated.

Advertising