Switching off the engine – HATZ Diesel 4M42 User Manual

Page 47

Advertising
background image

NOTICE

i

If the electronics indicate a problem continuously for more than
15 minutes without interruption (flash code - display lamp (5)),
the engine switches off automatically.

▪ If the problem persists, the engine can be started but only

for another 15 minutes.

▪ If necessary, contact your nearest HATZ service station.

Electrical automatic shutoff (additional equipment)

The distinguishing feature of the electrical automatic shutoff is brief flashing
of all indicators after turning the starting key to position "I".

NOTICE

i

▪ If the engine stops again immediately after starting, or stops

independently during operation, this is an indication that a
monitoring element of the automatic shutoff has been acti-
vated.

▪ Remedy the malfunction before further starting attempts

(see the chapter 9.1 Troubleshooting, page 93).

▪ Despite the automatic shutoff, check the oil level every 8-15

operating hours (see the chapter 7.9 Checking the oil level
and adding oil if necessary, page 53
).

▪ If the engine switches off due to an electrical fault signal or

due to insufficient oil pressure with the aid of the automatic
switch-off, an emergency start can be attempted by the
user. The user must bear responsibility for any resulting
damage (see the chapter 9.2 Emergency start, page 99).

7.6

Switching off the engine

Methods of switching off the engine

CAUTION

Danger of injury from unauthorized access.
There is a danger of injury if unauthorized persons handle the
machine.

▪ Protect the crankhandle and starting key against unauthor-

ized access upon breaks in operation or after completing
work.

2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42

Operation and use

HATZ

Operator's Manual

47