HATZ Diesel 4M42 User Manual

Page 77

Advertising
background image

NOTICE

i

▪ The pressure must not exceed 5 bar.
▪ A distance of approx. 150 mm must be maintained between

the filter cartridge and the compressed air gun.

▪ Even minor damage in the areas of the sealing surface, filter

paper or filter cartridge makes it impossible to reuse the fil-
ter cartridge.

Overview

Clean the filter cartridge

Check the air filter cartridge

Pos.

Designation

1

Sealing surface

Procedure

Step

Activity

Dry contamination

1

Blow out the filter cartridge with dry compressed air from the in-
side to the outside until dust no longer emerges.

2

Check the sealing surfaces (1) of the filter cartridge for damage.

3

Check the filter cartridge for cracks in the filter paper and other
damage by holding it against the light at a slant or letting light
from a lamp shine through it.

4

Replace the filter cartridge if necessary (see note).

Moist or oily contamination

1

Renew the filter cartridge.

2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42

Maintenance

HATZ

Operator's Manual