Type of fault

Possible causes

Remedy

Chapter

Fuel prefilter is
clogged.

Change the fuel
prefilter.

8.2.9
Changing
the fuel pre-
filter,
page 72

Fuel filter is clog-
ged.

Change the fuel fil-
ter.

8.2.14
Change the
fuel filter,
page 83

Fuel supply is inter-
rupted.

Systematically
check the entire
fuel supply.

Stop signal from
monitoring ele-
ments that are as-
sociated with the
automatic switch-
off (additional
equipment):
▪ No oil pressure.
▪ Dirty air filter

unit.

▪ Faulty three

phase alternator.

▪ Check the oil lev-

el.

▪ Check the de-

gree of dirt con-
tamination of the
air filter, and
clean or renew it
if necessary.

▪ Contact the Hatz

service station.

7.9 Check-
ing the oil
level and
adding oil if
necessary,
page 53
8.2.10
Maintaining
the dry air
filter,
page 74

Engine switches off
spontaneously dur-
ing operation.

The tank ran out of
fuel during opera-
tion

Fill with fuel.

7.7 Refuel-
ing, page 50

Fuel prefilter or fuel
filter is clogged.

Change the filter.

8.2.9
Changing
the fuel pre-
filter,
page 72
8.2.14
Change the
fuel filter,
page 83