10

Perform a leak tightness test by activating the manual lever.

11

After completion, insert the access cover to the fuel feed pump
back in the side wall.

12

Mount the capsule and air guide parts again.

Overview 4L42C and 4M42

Pos.

Designation

1

Drain plug

Preparation 4L42C and 4M42

Step

Activity

1

Close the fuel lines on the filter housing.

2

Place a suitable container under the filter to collect emerging
fuel.

3

Release the drain screw (1) and drain the fuel.

2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42