HATZ Diesel 4M42 User Manual

Page 94

Advertising
background image

Type of fault

Possible causes

Remedy

Chapter

After every extended period of disuse, if
you experience difficulties starting the
engine that can be eliminated by activat-
ing the feed pump for a lengthy period,
check that the fuel system is correctly
sized.

6.2 Assem-
bly instruc-
tions,
page 31

Insufficient com-
pression:
▪ Wrong tappet

clearance.

Check the tappet
clearance and ad-
just if necessary.

8.2.12
Check and
set the tap-
pet clear-
ance,
page 78

▪ Cylinder and/or

piston ring wear.

Contact the Hatz
service station.

▪ Faulty automatic

decompression.

Contact the Hatz
service station.

Injection nozzle is
not functional.

Contact the Hatz
service station.

Torn cooling fan
belt.

Renew the poly v
belt.

8.2.16 Re-
newing the
poly v belt
and check-
ing the func-
tion of the
switch-off
unit,
page 89

At low tempera-
tures

Pre glow system is
faulty (additional
equipment).

Contact the Hatz
service station.

Fuel gelled due to
insufficient cold re-
sistance.

Check whether the
fuel that emerges
from the detached
fuel feed line di-
rectly at the injec-
tion pump is clear
and not cloudy. If
the fuel has gelled,
either warm the en-
gine or drain the
entire fuel supply
system. Fill with a
temperature-resist-
ance fuel mixture.

4.2 Fuel,
page 23
7.7 Refuel-
ing, page 50
8.2.9
Changing
the fuel pre-
filter,
page 72
8.2.14
Change the
fuel filter,
page 83

Faults

2-4L41C, 2-4M41, 2-4M41Z, 4L42C, 4M42

94

Operator's Manual

HATZ

Advertising
This manual is related to the following products: